What size supply duct for 3 ton unit - 12" flex at the recommended residential velocity of 600 Ft/min gives almost exactly 500 cfm. Double that and you're at 1000 cfm which is exactly what a 2.5 ton unit needs (400 sq' per ton). The can size at 14x24 is plenty as well. 600 fpm is not all that fast so that's why it doesn't "feel" strong. It will make for a quiet and very efficient ...

 
To know the size of the return air duct for your four-ton unit, use this formula: For a rectangular duct, multiply the size of the AC by 144 square inches, 4×144=576. The square root of 576 is 24, so the size of a rectangular return duct. For a round duct, you will need the CFM rating, which is 400 per ton. Multiply 4×400.. Apush 2023 exam released

Here are two examples: a right and a wrong way to design this ductwork. The first (right) way uses 6" diameter pipe run all the way to the planer from the cyclone. This design will work and be able to deliver the desired 800 CFM. The second (wrong) way uses all 4" pipe run from the cyclone to the planer. This design will not get the desired ...ESP 1.2IWC equal both supply and return. temp split 12* registers/return grill. Flex is R-4.2 located in attic. Plenums and ducts except for the added returns and 1 supply are from the original system. Returns 16, 14. 14 whyees to 2, 12" one put in a small bedroom. Supply's 7, 7, 8, 10, 10, the second 10 was added.DIY 36,000 BTU 3-Ton 3-Zone 21.5 SEER Ductless Mini-Split AC and Heat Pump with 9K+12K+18K & 16,16,25ft Lines. ... diy mini split. ac unit. mini split. heat pump. 1 ton mini split air conditioners. 9000 btu mini split air conditioners. Explore More on homedepot.com. Heating, Venting & Cooling. Shop Wifi Mini Split Systems; ... California Supply ...Repairing a PC power supply may seem challenging, but many issues with power supplies are actually fairly simple to diagnose and repair. In particular, you may have to replace your...Documents Details. Reheat Unit. 40VMZ. Type: Reheat. Capacity Range (Tons): 0.75 - 2.0. Documents Details. A variety of quiet, indoor fan coils with up to ten cabinet styles with a wide range of capacity from 0.6 to 8.0 tons.For the main trunk a 16" metal trunk line will flow 1210-CFM at 867-fpm velocity. To convert for fiber board: 156" *X 16"= 256 *X 0.7854 = 201.0624-sq.ins| divided 144 = 1.3962666-sf of open area. Well, 1210-CFM / 1.3962666-sf of open area = 866.58-CFM, close to my other software number of 867-CFM. Return air grilles & filter grilles need also ...What size of return duct do I need for a 3Ton HVAC air-handler. Answered in 4 minutes by: HVAC Technician: HVAC Guru. Hello, Typically a 16X20 would be fairly standard for most applications on a 3 ton unit. However if you want superior air flow I would highly suggest putting in a 20X20 as that gives you far better airflow hands down.A conventional duct system is designed for .1 or .2 in.wc. (inches of water column) of duct pressure. The Unico system operates at approximately 1.5 in.wc. duct pressure. A conventional system will have supply duct velocity of 500 to 700 fpm, the Unico system is 1500 to 2000 fpm and the outlet supply velocity will be 1000 to 2000 fpm.It has a 2 ton Skymark HVAC unit that produces 750 CFM for heat and 800 CFM for A/C. The unit is located in a bedroom closet. There are 2 supplies coming off the HVAC unit supply plenum: - 16 x 6 rectangular sheet metal duct feeding the bedroom. - 12 x 6 rectangular duct feeding the living room (and remainder of apt), fed by 9" flex duct elbow ...Note: For duct pressure control, a Duct Static Pressure Transducer is included. However, 5/16- or 1/4-inch plastic tubing and a static pressure probe must be field supplied/installed approximately 3/4 down the longest supply duct run. Single Zone VAV - Series 100 is available for single zone variable air volume (VAV) ap-My 19yo AC (3.5 ton Trane) finally bit the dust and doing a complete system replacement though will likely leave most duct work. This unit serves our upstairs (about 2000 sq ft). A 2.5 ton serves our downstairs (about 1300 sq ft). Central NC. House has no shade and gets a lot of sun (dark roof, dark brick) and the attic naturally gets extremely ...Much like the recommendation to install dampers, I almost always emphasize adding a second return when replacing ductwork.During a major energy upgrade that we recently completed, we had two return ducts- a 14″ in the main house and a 12″ return duct in the master bedroom. That was for a 1.5 ton system and the static was 0.33 inches of water column (IWC).How Air Conditioner Sizes are Measured. The cooling capacity of an air conditioner is based on the number—in tons—of British Thermal Units (BTUs) it can remove in an hour.. The industry standard for central air conditioning units is that they begin from a minimum size of 1.5 tons and get larger in half-ton sizes. So, 1.5-ton, 2-ton, 2.5-ton, and so onHi, I have a 5 ton a/c unit cooling just shy of 2,000 sq ft. My air return is built into a sealed box positioned between 2 walls at the bottom of the second floor. ... 2 to 3 feet of horizontal duct, and another 90 degree elbow to connect the duct to the unit. Thanks for your help! ... I am trying to figure out what size supply trunks, return ...Remember you’ll want ~400 CFM per ton. The lowest I’d go is 350 per ton for very humid conditions. You have a 3 ton unit which is 1200 cfm’s. As r mentioned 1 ton = 400 cfm’s. If that 14″ round return is all you have it is undersized for your unit. Basic Return Duct Sizing Made Simple.2 ton AC unit costs $1,700 – $2,200 3 ton AC unit costs $2,200 – $2,500 4 ton AC unit costs $2,500 – $2,900 5 ton AC unit costs $2,900 – $3,500 ( a 5 ton unit is extremely powerful and is not required for most homes) In general, you can roughly add $400-$700 for each additional ton, as the units go up in size. Residential Central AC ...5.2 Rectangular Ducts 7 5.3 Oval Ducts 8 6.0. SUPPLY DUCT CONFIGURATIONS 8 6.1 Extended Plenum Systems 8 6.2 Reducing Trunk System 10 ... ductwork is only increased by one standard size. ... The pressures are total pressure and include all losses through the air source unit, the supply ductwork, and the air terminals, return air grilles, and ...2 ton does not give you 1000cfm. 2 ton gives you 800 cfm. Also, you need to tell us if you're measuring your return duct by inside measurements or outside measurements. Yes, I understand that 2 ton gives me 800 cfm. The picture just shows that my 12x16 gives me 1000cfm (sufficient for my units' return, maybe).Wiring Diagrams. *Based on sound pressure levels during operation of Lennox's CBA38MV-036 with factory-installed filter compared against 3-ton units of the leading competitors representing the majority of the total air handlers of like class sales volume in North America at equivalent external static pressure when set up per Section 4.5.3 of ...What size return duct do I need for a 3-ton unit? A 3-ton unit uses approximately 1200 CFMs or approximately 400 CFMs per ton. The lowest you should go is about 350 per ton when the conditions are very humid.In most cases, if you are installing ducts in each room where there is a supply, you will want to go with the same size as your supply vents. If you are installing just one or two return vents, you will want to go with a 12-inch return for 2-ton units and lower. 14- inches for 3 and up. 16-inch should be suitable for 4 ton systems, whereas 5 ...1. Yes, my "Ductulator" says a 12" diameter duct (with insulation on the exterior of the duct) is a little small, but barely adequate for a 2 ton unit. If I was sizing it I'd use a 14" diameter with a friction loss of .09 per 100 feet of duct on the SUPPLY side and .07 on the RETURN side. However, your 12" duct will make the air ...What size round duct is best for a 2.5 ton unit on a mobile home that's 13 x 60. Contractor's Assistant: Did you double-check the thermostat? And what about the unit's filters? I need to replace my duct system, what size round duct is best for a 2.5 ton unit? on a mobile home that's 13 x 60y duct systemHelping you plan your home improvement project, from start to finishApr 17, 2020 · Forum Rules. I currently have a 3 ton with 16 inch metal return duct work. I was told this by a contractor: 3 ton heat pumps with the new r410a refrigerant recommended size is 18" on the return duct. Otherwise you should expect issues with your system typically in winter time. I wanted to verify with you guys since the cost of upsizing the ... Infections, gallstones, and cancer can result in bile duct problems. Discover the types, causes, symptoms, and treatment of bile duct diseases. Your liver makes a digestive juice c...The return duct size of 16 inches is insufficient for a 3-ton AC. A 3-ton AC should have a return duct 18 inches in diameter. For a 3-ton AC, a 16-inch return duct is too small. Ducts that are too small will increase static pressure, which will cause too much noise when air passes through the AC. The heating unit will be overworked because ...highlights. The Goodman® GPH14M 14 SEER Packaged Heat Pump provides energy-efficient cooling and heating performance in one self-contained unit. The Goodman GPH14M is housed in a heavy-gauge, galvanized-steel cabinet that offers a high-quality, UV-resistant powder-paint finish and allows for a ground-level or rooftop mount.Let say you have a 3-ton HVAC unit and the airflow is about 1200 cfm. Your return air closet only can fit a 10″ wide duct. So, let’s try to use a 10×28 duct and see if the performance is equivalent to the 12×22 duct: Equivalent diameter = [1.3 x (ab) 0.625] / [(a+b) 0.25] Equivalent diameter = [1.3 x (10×28) 0.625] / [(10+28) 0.25]We need it to move around 400 CFM of air. If it can't, adding return air might be the solution. Or, depending on your situation, there could be some other path to increased airflow. Whatever the case, we can help! If you live in Metro Atlanta and think your HVAC system ought to be moving more air, drop us a line!We would like to show you a description here but the site won't allow us.RuppAir's HVAC unit is ETL-listed to the following standards: Standard for Safety Heating and Cooling Equipment ANSI/UL 1995, CSA 22.2 no. 236; American National Standard/CSA Standard for Gas Unit Heaters and Gas-Fired Duct Furnaces ANSI Z83.8-2013, CSA 2.6-2013.Aluminum Supply Tubing, 2" x 25', R3.3, TFS, 4/bx (UPC-25T-4, Unico) ... It can deliver up to 9 tons of air conditioning in the same space as a 3-ton traditional unit. Technical Specifications: Duct Size: 2.0: Matching Duct Type: Aluminum Core: Duct Shape: Round: Material: Multiple: Flex or Rigid Duct: Flexible: R-Value:Most of us are familiar with small tonnage units from 2 to 15 tons, but how big is a 150-Ton unit. Here is a quick size comparison between a 40-Ton to 75-Ton Rooftop Unit and a 2020 Tesla Model S. ... The supply and return air duct connections come off the bottom with the option on some models to have a side discharge configuration.Using the chart, you'll see that for a 12" round flex duct, maximum CFM is 480 CFM or 500 CFM depending on the friction rate. Duct size for 115 CFM. Find the CFM closest to 115 in the table above. It will be found in different columns depending on the friction rate. If there isn't an exact match, go up to the duct size.It's a two ton unit and I can't figure out how to size the plenum. The Air handler is central in the attic, only 6 runs so I'm going to do a radial duct system. Example. System Info-. 2 ton system with supply air opening of 16.375 x 11.3 Inches. 6 flex duct runs total; 5 8" runs 1 4" run. Longest run is 15 feet. 1.Oct 10, 2023 · To accommodate the air flow rate of a 5-ton unit, the standard ductwork size estimate according to shape is as follows: Round shape (diameter): 16.8". 16.9". Rectangular shape (H x W): 10" x 25". 12" x 20". 15" x 16". Duct sizing is a complex process greatly influenced by many factors. 2 Jul 2021 ... ... Duct Crimper: https://amzn.to/2TxE1pT Klein ... 3:11 Jumper Ducts & Transfer Grilles 4:48 Central Return Air Option 6:00 Supply ... ton 11:30 ...I currently just have one return that comes in to my garage and it is 12 x 18. He said that 5 tons need to breathe alot and that he wants to get it as close to 20 x 20 as possible. Another thing that my current unit has is a "U" pipe that connects to the bottom of my evaporator unit and the return pipe. He said he will.20. Post Likes. Correct return duct size for 4 ton unit? There seems to be different data on the correct size duct for return sizing on a 4 ton unit. Based on a 4 ton, …I'm having a new AC unit and furnace installed, and I have a question about the duct sizes. I had a manual J performed, and they recommended a five ton AC unit. My existing duct is horizontal 12"x27" at the beginning, then it bends upwards and transitions to a 12"x 24". There is ten inch roudn duct shooting off inbetween. This seems small to me …The supply duct I'm sure can handle a little more airflow I don't think that's going to be that bad. Is there any way to increase the size of the return duct or add return to another part of your house? ... On my heat pump I have call 3 ton unit I have 2 1/2 tons moving through the air handler and I love the way it works especially in the heat ...baytemspfg1a/b supply duct flange kit tem6a0b24-tem6a0d60 ... unit size (tons) speed setting airflow setting dip switch setting airflow power external static pressure 2 ton 3 outdoor 2 ton. 22-1907-1e-en ton. tem6a0b24h21s, tem6a0b30h21s tem6a0c36h31s, tem6a0c42h41s. handler. heat.We would like to show you a description here but the site won't allow us.1.5 ton duct. i'm going to be installing a new duct system in the attic.900 sqft house 1.5 ton unit.total trunk line going to be about 20ft what size should my trunk line be? there will be about 6 6inch runs...thanks. To properly size your truckline you would have to calculate the duct size for your equipment.What size line set for a 4 ton unit? For a 4-ton air conditioning unit, you can consider using a line set with a 7/8-inch (22.2 mm) suction line and a 3/8-inch (9.5 mm) liquid line. ... The rule of thumb for HVAC duct sizing is that the total duct area should be around 1 to 1.5 square inches per CFM of air flow.Step 2: Size the Heat Pump. We need to produce 38,000 BTUs/h to meet the heating demand. We will use that number to select a heat pump that can handle the load. 12,000 BTUs per hour is one ton of capacity, so we will need a 3-ton unit. Keep in mind that the nominal rating for heat pumps from different manufacturers will differ and not all 3-ton ...Now size the ducts and branches so that the velocity is 600 to 900 ft. per minute for sheet metal and 600 ft per min. Maximum for flex duct. (Example: a 7" dia. round flex duct has an area of 38.5 sq. in. {or .267 sq.ft.} and 140 cfm will pass through it with a velocity of 539 ft. per min.) This is rule of thumb information and experienced ...Comfortmaker Ion™ CSH6 – The best single-stage 3-ton heat pump. With a cooling capacity that varies from 1.5 to 5 tons, the Comfortmaker Ion™ CSH6 heat pump is suitable for both small and large spaces. The unit features a single-stage scroll compressor and a single-speed fan motor that ensure stable output. Moreover, the CSH6 can switch ...In the HVAC world, "rules of thumb" often dictate equipment sizing. Using a common rule of thumb mandating 1 ton of cooling capacity for every 600 square feet, a contractor might look at a house and say, "Ok, this one's 2,400 square feet. Cool, dude! Let's put in a 4-ton air conditioner.". Not cool, dude.1 Answer. Sorted by: 1. Yes, my “Ductulator” says a 12” diameter duct (with insulation on the exterior of the duct) is a little small, but barely adequate for a 2 ton unit. …What size ductwork do I need for a 3-ton unit? 1 ton of cooling is equal to 400 CFM approximately. Hence, the airflow of a 3-ton heat pump is roughly 1200 CFM (400 x 3).Electric Heat (Unit Size Allowed) Sensors A Cabinet Options. 5190086-YTG-H-0220 ... through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. ... Electric) 3-5 ton units with no factory installed economizerFlat Elbows & Air Duct Reducers (19) Category Flat+Elbows+%26+Air+Duct+Reducers Flat Elbows & Air Duct Reducers 5' Length (14) Category 5%27+Length 5' Length End Caps (10) Category End+Caps End CapsProper sizing for Supply Trunk. I currently have, in the attic, a 2" duct board supply trunk, with interior dimensions of 12x20", giving an area of 240 in2. It is …Basis. 1 No - - No No There is no fan to shutdown; system does not an “air distribution system”. - NFPA 90A 6.4.2.1 2 Yes Yes Any No No Not required for fan units whose sole function is to remove air from inside building. - NFPA 90A 6.4.2.3 3 Yes No < 2,000 CFM No No Fan is too small to require shutdown.Mobile home package units operate at a higher static pressure than a standard split system. The duct in the mobile home is usually 12 * 4. Running a 16 inch flex to that is not going to help. Want to help the effiencency install a larger return. Get rid of some of the static pressure on that side.Let's say your supply duct is 16" by 8," and there's so much static pressure air is restricted. It wouldn't be out of the realm of possibility to increase it to 18" by 8" or 20" by 8" to get more air flowing through it. Or, if the supply duct is too big, you can replace the first four or eight feet, then taper it down.2. The size of your air conditioning unit. 3. Airflow velocity. 4. Friction loss. 5. The static pressure of the HVAC unit. In order to calculate the duct size, proceed as follows – 1. Look on your furnace to see how many BTUs (British Thermal Unit) it produces. This information is usually given on the furnace plate. Divide that number by ...Units Digit 1 — Gas Heating Equipment G = Gas Heating Equipment Digit 2 — Product Type L = High Efficiency Indoor Duct Furnace Digit 3 — Fuel Type s a Gl a r uN=t aN) e n a p o r P ( s a GP=P L Digit 4 — Development Sequence D = Fourth Generation Digits 5, 6, 7 — Input Capacity Single Furnace 010 = 100 MBh 030 = 300 MBh 015 = 150 MBh ...That would be a 6" duct with a 6"x6" grille or 6"x8" grille and boot for 100-120 cfm to each of 4 registers. Or a 7" duct for 160-180cfm per 6"x8" boot and register. Throw and velocity make a big difference on small right sized systems. The registers Can't Be stamped cheap registers.Multiply it by 144 to get the grille size in square inches and choose your preferred grille size based on that. For instance, 400 cfm ÷ 350 x 144 = 164.57 sq.in. So, the possible grille sizes are 20×8 (160 sq.in), 16×10 (160 sq.in) or 14×12 (168 sq.in) depending on your duct size. The above way is based on the grille sizing formula which:What size return duct do I need for a 3-ton unit? A 3-ton unit uses approximately 1200 CFMs or approximately 400 CFMs per ton. The lowest you should …Supply trunk (one continuous trunk) with: 8"x8" x 14' section with 3 - 6" supply branch runs. 8"x16" x 25' section with 6 - 6" supply branch runs. 8"x8" x 8' section with 3 - 6" supply branch runs. So I have 12-6" supplies to my rooms. All duct is hard ducted and insulated to R-5. I am having central air installed in my 70 year old MA Cape home. 1900 Sq Ft. One contractor say to go with a 3.5 ton. One says 2.5 because of my small duct size. The ductwork measures 8 by 14 at the furnace but 6 by 10 inches at the wall vents. What size of return duct do I need for a 3Ton HVAC air-handler. Answered in 4 minutes by: HVAC Technician: HVAC Guru. Hello, Typically a 16X20 would be fairly standard for most applications on a 3 ton unit. However if you want superior air flow I would highly suggest putting in a 20X20 as that gives you far better airflow hands down.Cubic feet per minute is calculated by multiplying the size of the HVAC unit (in tons) by 400. Divide the answer by your home's square footage to find out total CFM. ... Duct Size vs. CFM. Round ducts are available in flexible and metal pipe forms. In the FREE guide below are a few duct size estimates based on duct size, in inches (flexible ...One is that the supply plenum should be no larger than the blower opening off the top of the air handler, which seems small, at only 16x11". But most opinion, particularly from the HVAC supplier, is that the plenum should be the same size as the overall A.H. cabinet size, which is 17.5 x 21". That's how the current one is.Hitachi Ductable AC is available in 1.5 Tons, 2 Tons, 3 Tons, 5.5 Tons, 8.5 Tons, 11 Tons, 16.5 Tons. This range of air conditioners offer factory charged and tested refrigerant, ease of installation, ease of operations and safety features that are customized to best meet the consumers' needs. Powerful (More Efficient) • Part Load Operation • Phase Starting of Compressor Comfort (Ease of ...One guy — looked at our unit, asked me the number of registers, and looked at our fuse box. He said we should upgrade to a 3.5 ton, 14 ser vs the 3 ton 10 ser we currently have. The second guy, crawled under our house, and took measurements of the size of the house and told us that the duct size was too small.Fan Coil Units. ENVIRO-TEC fan coil units are designed to exceed the stringent quality standards of the institutional market, while remaining cost competitive in the light commercial segment of the market. A variety of models - each with an extensive list of standard features - allows unparalleled design flexibility.A 3 Ton air conditioner is typically necessary for homes up to 1,500 to 2,500 square feet. Other factors such as climate, home insulation, and number of windows can also influence the right air conditioner size for your home, so be advised that this is just a general example. For a slightly smaller home you might want to consider a 2.5 ton unit.What size return air grill for a 48000 BTU heating system? 48,000 btus is equal to 4 tons of air flow, 12,000 btus per ton. You need 144 sq in per ton.If you dropped the CFM to 350-cfm per ton of cooling the 18 inch metal RA duct would deliver at 991-fpm, which is really too high for RA flow, friction rate is also high for RA @0.09". For RA @2000-CFM I'd want a 22" metal duct @758-fpm & 0.04" friction Rate/100'.Installation Figure 34. Cooling and gas/electric —10 tons high Figure 36. 4 to 6 ton high efficiency units, 6(074)-8.5 efficiency— horizontal airflow, supply and (Microchannel) high efficiency units and 6 to 10 return ton standard efficiency units - down flow supply and return air openings w/ through- the- base utilities 3 7/8"...Run a large size plenum under home from Pkg unit. Run new branches to existing registers using six round 26ga pipe or insulated flex. Just slow, not stupid. ... on the master bedroom side. Shorten the helper up. So that it taps into the supply duct between the first supply for the master, and the last supply for the dining room. When posting in ...That duct size can handle twice what your asking to do . ... I currently have a 3 ton unit but am looking at upgrading to a 3.5 ton so addition can have a vent. Do I have to create a bigger intake? ... Question regarding sizing supply and return extended plenums. This is a 2 story colonial type house with a half basement. Its 1,770 square feet ...It’s why you should depend on Merts Heating & Air Conditioning which has been serving Illinois and Northwest Indiana since 1952. Learn more about the services we offer by liking us on Facebook and following us on Twitter. HVAC systems will have two plenum boxes, one on the supply side and one on the return air side serving as the …Frequently Asked Questions. What return duct size do I need for a 2 Ton unit? For a 2 ton unit you can use either a 19″ flex duct or one of the following rectangular ducts: 14″x13″, 15″x12″, 17″x11″, 18″x10″, …Basis. 1 No - - No No There is no fan to shutdown; system does not an “air distribution system”. - NFPA 90A 6.4.2.1 2 Yes Yes Any No No Not required for fan units whose sole function is to remove air from inside building. - NFPA 90A 6.4.2.3 3 Yes No < 2,000 CFM No No Fan is too small to require shutdown.The unit is a "Nordyne" model GB3BM-024K-AB, 2.5 ton,unit on first floor, same as old unit and plenty for this house. There is about 24-25 ft. of line. I took the temp about 10 inches above the coil. Return air flow is good, best on the first floor right next to the blower. Line sizes: Old line, 5/8 and 1/4 Unit line, 3/4 and 3/8However, upon request, many grille suppliers do provide custom-made sizes at a higher price. Return air grilles are standardized based on 2″ per size increase. The smallest return air grille is usually starts at 4 inches by 4 inches. So, the next corresponding return air grille size includes 4×6, 6×6, 6×4, 8×6, 4×8 and so on.Table of Contents. CFM Sizing Chart For Flex Round Ducts (50-1,700 CFM) CFM Sizing Chart For Metal Round Ducts (50-2,000 CFM) 4-Inch Rectangular Ducts Size Chart (60-330 CFM) 6-Inch Rectangular Ducts Size Chart (60-775 CFM) 8-Inch Rectangular Ducts Size Chart (90-1,500 CFM) 10-Inch Rectangular Ducts Size Chart (120-2,350 CFM)A plenum is a distribution box attached to the supply outlet of the air handling unit. And the purpose of plenum box is to distribute the cooled or heated air to several spaces. ... Download McQuay Duct Sizer for HVAC Duct Sizing. 10/30/2016 01:14:00 AM. Download AutoCAD Fonts Library - Free SHX Fonts ... Download Electrical Cable Size ...

3. Size the gas line to the furnace adequate enough to prevent undue pressure drop and never less than 1/2(. 4. Install a drip leg or sediment trap in the gas supply line as close to the unit as possible. 5. Install an outside ground joint union to connect the gas supply to the control assembly at the burner tray.. Geode cracking near me

what size supply duct for 3 ton unit

that duct needs to be upsized to flow at 900 to 1,100 fpm. that will drop the static pressure noticeably ... how much depends on the length of the main supply duct and size of the other ducts.. Supply duct size coming off of the 12 x 19" opening at 4,000 cfm needs to have an inside area of 1.8 to 2 square feet. with a total equivalent length of ...have a carrier model 50xt048-3 4-ton heat pump package unit. what is the min. return and supply ductwork size the return is about 12' from the return filter grill box and same for the supply to trunk … read moreIntroducing the Carrier Ducted-SLIM 42TKS048-71UCR1 Split System 4.0 ton - the perfect solution for cool and comfortable spaces. Its R-401A refrigerant ensures eco-friendliness and superior cooling. The 4.0 ton unit is ideal for commercial or residential use. The power supply of 400-3-50/230-1-50 (CU-FCU) is compatible with most sources.Here we presume that all AC units have a 10 EER rating (most have a bit higher EER rating but by using a 10 EER rating we approximately account for the voltage drop as well). That means that a 3-ton AC unit (36,000 BTU) has a max. wattage of 3,600W. Similarly, a 2-ton unit (24,000 BTU) has a max. wattage of 2,400W.Originally Posted by tigergrad97. 12" -14"...by appearance anyway. 2-14" would be ok for 3 tons (depending on length and bends/turns. So your a bit small for 3 tons if 1 is 12" and the other 14". Which may be why your current 3 ton struggles on some days. Reply. 11-10-2010, 09:09 PM #10. tedkidd. Professional Member*.Each ton of refrigeration can cool 12,000 BTUs each hour. Learn how to calculate air conditioning tonnage by multiplying the unit's tonnage by 12,000. Using this formula: A 2-ton unit can cool 24,000 BTUs per hour. A 3-ton unit can cool 36,000 BTUs per hour. A 4-ton unit can cool 48,000 BTUs per hour.Let say you have a 3-ton HVAC unit and the airflow is about 1200 cfm. Your return air closet only can fit a 10″ wide duct. So, let’s try to use a 10×28 duct and see if the performance is equivalent to the 12×22 duct: Equivalent diameter = [1.3 x (ab) 0.625] / [(a+b) 0.25] Equivalent diameter = [1.3 x (10×28) 0.625] / [(10+28) 0.25]DRASH 5 Ton Turf Cart - Turf cart-mounted ECU system with combined 60K BTU cooling/60K BTU heat. Dual 8 Ton ECU Trailer - Trailer-mounted ECU system with combined 192K BTU cooling/92K BTU heat. E2CU 18K and EEECU-M18 SEL - ECUs delivering 18K BTU cooling at 130°F. M18 SEL includes full onboard diagnostics. EEECU 9K and E2CU 18K- ECUs ...Feb 19, 2024 · The output from the calculator will give you up to 4 duct size options to choose from: 1 round size and up to 3 rectangular size options. The round duct size gives the size in diameter; The rectangular duct options give the width and height. You can choose 1 of the 4 sizes for your home based on what work best for its layout. Small Rooftop Units 3 to 15 Tons ... NUMBER USAGE MODEL SIZE TONNAGE SUPPLY AIR BRACKET SUPPLY AIR PICKUP TUBE RETURN AIR BRACKET RETURN AIR PICKUP TUBE CRSMKKIT003A00, CRSMKSEN003A00 48FC, 50FC, 50FCQ 04-07 3 to 6 48TC001809 (tube) ... ed to one or two compatible duct smoke sensors. The clearWhat size of return duct do I need for a 3Ton HVAC air-handler. Answered in 4 minutes by: HVAC Technician: HVAC Guru. Hello, Typically a 16X20 would be fairly standard for most applications on a 3 ton unit. However if you want superior air flow I would highly suggest putting in a 20X20 as that gives you far better airflow hands down.The right size of return duct for a 3.5 ton AC is 22 X 22 inches. In the case of a 4 ton AC, it’s 24 X 24 inches. And for a 5 ton AC, the correct size is 27 X 27 inches. Calculate the return duct size. And multiply AC tonnage by 3.14 for round and 144 square inches. This is for rectangular ducts. Now, we have all the answers and calculations ...The duct is 250mm and approx total is 1 meter duct run on each side of the coil. This unit works equally well in heating or cooling but I have had to boost the static pressure of the fan to say 30PA. The 2nd unit though serves two rooms (spare bedroom & bathroom), I use the same style and size return and supply grills.Built-in drain pump allows for installation of slim duct unit in smaller spaces than traditional units. Smart System: Auto Mode. When the system is initially turned on, the fan speed is HIGH to reach the set temperature as quickly as possible. The fan speed will automatically adjust downward as the room begins to reach the set temperature.Run a large size plenum under home from Pkg unit. Run new branches to existing registers using six round 26ga pipe or insulated flex. Just slow, not stupid. ... on the master bedroom side. Shorten the helper up. So that it taps into the supply duct between the first supply for the master, and the last supply for the dining room. When posting in ...Central AC Btu Calculator. Locate your climate zone on the map above and provide your square footage and we'll determine how many BTUs your heating system should have. Climate Zone: See the climate zone map above to find your home's climate zone. Home Size (sq ft): Insulation Condition: Sun Exposure: Recommend AC Unit Size: 2 - 2.5 Ton.The size of the HVAC unit you'll need for the whole house can be found using the unit's average output and the square footage of your home. As a rule of thumb, you'll need 400 CFM of airflow per ton of air conditioning; it takes about 1 CFM of air to heat or cool 1 to 1.25 square feet of floor area. Last, you'll need to understand duct friction.Here we presume that all AC units have a 10 EER rating (most have a bit higher EER rating but by using a 10 EER rating we approximately account for the voltage drop as well). That means that a 3-ton AC unit (36,000 BTU) has a max. wattage of 3,600W. Similarly, a 2-ton unit (24,000 BTU) has a max. wattage of 2,400W.The first stage of a gas heat Sun™ Pro unit provides 70% or 75% of the heating capacity for the 3 to 5 ton units. The 6.5 to 12.5 ton units reach 60% heating capacity on the first stage. Convertible airflow design A convertible airflow design provides maximum field flexibility while minimizing inventory. The side ducts are covered when the ....